Watts 957ZRPDA User Manual

Browse online or download User Manual for Accessories for water Watts 957ZRPDA. Watts 957ZRPDA User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
For Health Hazard Applications
ES-957RPDA/957NRPDA/957ZRPDA
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
Series 957RPDA,
957NRPDA,
957ZRPDA
Reduced Pressure Detector
Assemblies
Sizes: 2
1
2" – 10" (65 – 250 mm)
Series 957RPDA, 957NRPDA, 957ZRPDA Reduced Pressure
Detector Assemblies provide protection to the potable water
system from contamination in accordance with national plumb-
ing codes. The 957RPDA, 957NRPDA, 957ZRPDA are normally
used in health hazard applications to protect against back-
siphonage and backpressure. The Watts 957RPDA, 957NRPDA,
957ZRPDA are used to monitor unauthorized use of water from
the fire protection system.
Features
Extremely compact design
70% lighter than traditional designs
304 (Schedule 40) stainless steel housing & sleeve
Groove fittings allow integral pipeline adjustment
Patented torsion spring check provides lowest pressure loss
Unmatched ease of serviceability
Replaceable check disc rubber
Available with grooved butterfly valve shutoffs
Bottom mounted cast stainless steel relief valve
Metered bypass to detect leakage or theft of water from the
fire sprinkler system
957NRPDAOSY
Specifications
The Reduced Pressure Detector Assembly shall consist of two
independent torsion spring check modules, a differential pres-
sure relief valve located between and below the two modules,
two drip tight shutoff valves, and required torsion spring check
modules and relief valve shall be contained within a sleeve
accessible single housing constructed from 304 (Sch 40) stain-
less steel pipe with groove end connections. Torsion spring
checks shall have reversible elastomer discs and in opera-
tion produce drip tight closure against reverse flow caused by
backpressure or backsiphonage. The bypass line shall include
a meter, small diameter reduced pressure zone assembly and
isolation valves. Assembly shall be Watts Series 957RPDA,
957NRPDA, 957ZRPDA.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - 957ZRPDA

For Health Hazard ApplicationsES-957RPDA/957NRPDA/957ZRPDAJob Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––

Page 2 - Approvals

Available ModelsSuffix:OSY – UL/FM outside stem and yoke, resilient seated gate valvesBFG – UL/FM grooved gear operated butterfly valves with

Page 3 - 2" (65mm)

0 100 200 300 400 500 gpm0 380 760 1140 1520 1900 lpm 7.5 15 fps 2.3 4.6 mps3" (80mm)0 300 600 900 1200 1500 gpm0 1140 2280 3420

Page 4

For additional information, visit our website at: www.watts.comES-957RPDA/957NRPDA/957ZRPDA 1151 © 2012 WattsUSA: Tel. (978) 688-1811 • Fax: (978)

Related models: 957NRPDA | 957RPDA |