ES-U009
Series U009
Reduced Pressure Zone Assemblies
Sizes:
1
2" – 2" (15 – 50mm)
Series U009 Reduced Pressure Zone Assemblies are designed to
protect potable water supplies in accordance with national plumbing
codes and water authority requirements. The swivel feature in the
series allows for it to be used in a variety of installations, including the
prevention of health hazard cross-connections in piping systems or
for containment at the service line entrance.
This series features two in-line, independent check valves, captured
springs and replaceable check seats with an intermediate relief valve.
Its compact modular design facilitates easy maintenance and assem-
bly access. Sizes
1
2"– 1" (15 – 25mm) shutoffs have tee handles.
Features
•Uniqueswivelunion
•Singleaccesscoverandmodularcheckconstruction
for ease of maintenance
•Topentry—allinternalsimmediatelyaccessible
•Capturedspringsforsafemaintenance
•Internalreliefvalveforreducedinstallationclearances
•Replaceableseatsforeconomicalrepair
•Bronzebodyconstructionfordurability
•Ballvalvetestcocks—screwdriverslotted
•Largebodypassagesprovideslowpressuredrop
•Compact,spacesavingdesign
•Nospecialtoolsrequiredforservicing
Specifications
A Reduced Pressure Zone Assembly shall be installed at each poten-
tial health hazard location to prevent backflow due to backsiphonage
and/or backpressure. The assembly shall consist of an internal pres-
sure differential relief valve located in a zone between two positive
seating check modules with captured springs and silicone seat discs.
Seats and seat discs shall be replaceable in both check modules
and the relief valve. There shall be no threads or screws in the water-
way exposed to line fluids. Service of all internal components shall be
through a single access cover secured with stainless steel bolts. The
assembly shall also include two resilient seated isolation valves, four
resilient seated test cocks and an air gap drain fitting. The assembly
shallmeettherequirementsof:USCManual8thEdition
;ASSEStd.
1013;AWWAStd.C511;CSAB64.4.ShallbeaWattsSeriesU009.
Does not indicate approval status. Refer to Page 2 for approved
sizes & models.
Test Cock No. 3
Test Cock No. 4
R.P. Zone
Water Outlet
Test Cock
No. 2
First Check
Module
Assembly
Second
Check
Module
Assembly
Relief Valve Assembly
Ball Type
Test Cocks
Now Available
WattsBox Insulated Enclosures.
For more information, refer to literature ES-WB.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
For Health Hazard Applications
Unique Swivel Union
1
1
2" U009M2AQT
JobName
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
JobLocation
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’sP.O.No.
––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Series U009

ES-U009Series U009Reduced Pressure Zone AssembliesSizes: 1⁄2" – 2" (15 – 50mm)Series U009 Reduced Pressure Zone Assemblies are designed to p

Page 2 - and 993 sizes

Available ModelsPrefix:U – union connectionsSuffix:QT – quarter-turn ball valvesS – bronze strainerLF – withoutshutoffvalvesAQT – 3⁄4"

Page 3 - Dimensions and Weights

Dimensions and WeightsU009QTmodel size (dn) dimensions Weight A B C in. mm in. mm in. mm in. mm lbs. kgs.U009QT 1⁄2 15 1213⁄16 326 45⁄8 1

Page 4

0 1 2 3 4 5 6 7 8 9 10 gpm0 3.8 7.6 11 15 19 23 27 30 34 38 lpm 7.5 fps 2.3 mpsCapacitiesPerformance as established by an independent testing labo