Installation, Maintenance, & Repair
Series 919 and LF919
Reduced Pressure Zone Assemblies
Sizes:
1
4" – 2" (8 – 50mm)
919QT
RP/IS-919
You are required to thoroughly read all installation instructions
and product safety information before beginning the installa-
tion of this product. FAILURE TO COMPLY WITH PROPER
INSTALLATION AND MAINTENANCE INSTRUCTIONS
COULD RESULT IN PRODUCT FAILURE WHICH CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY AND/
OR DEATH. Watts is not responsible for damages resulting
from improper installation and/or maintenance.
Local building or plumbing codes may require modifications to
the information provided. You are required to consult the local
building and plumbing codes prior to installation. If this informa-
tion is not consistent with local building or plumbing codes, the
local codes should be followed.
Need for Periodic Inspection/Maintenance: This product
must be tested periodically in compliance with local codes, but
at least once per year or more as service conditions warrant.
Corrosive water conditions, and/or unauthorized adjustments
or repair could render the product ineffective for the service in-
tended. Regular checking and cleaning of the product’s internal
components helps assure maximum life and proper product
function.
NOTE: For Australia and New Zealand, line strainers should be
installed between the upstream shutoff valve and the inlet of the
backflow preventer.
Its important that this assembly be tested periodically in compli-
ance with local codes, but at least once per year or more as
service conditions warrant. If installed on a fire sprinkler system, all
mechanical checks, such as alarm checks and backflow preven-
ters, should be flow tested and inspected internally in accordance
with NFPA 13 and NFPA 25.
WARNING
!
Testing
For field testing procedure, send for IS-TK-DL, IS-TK-7,
IS-TK-9A, IS-TK-99E AND IS-TK-99D.
For other repair kits and service parts, send for PL-RP-BPD.
For technical assistance, contact your local Watts
representative.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Series 919 and LF919

Installation, Maintenance, & Repair Series 919 and LF919Reduced Pressure Zone AssembliesSizes: 1⁄4" – 2" (8 – 50mm)919QTRP/IS-919You are

Page 2 - Installation Instructions

2Installation InstructionsSeries 919 and LF9191⁄4" – 2" (8 – 50mm)Air GapStrainerReduced Pressure Zone Assemblies Indoor InstallationFor ind

Page 3

3WARNING:Do not allow the drain line to empty directly into a drainage ditch, sewer system, or sump.NOTE: Relief Valve Discharge RatesThe Series 919 a

Page 4 - Servicing the Relief Valve

4NOTES: 1. No special tools are required to service the Series 919 and LF919 1⁄4" - 2". 2. Before servicing, make sure the water is turne

Page 5

5Servicing the Relief ValveSeries 919 and LF9191⁄4" – 2" (8 – 50mm)Quad-RingRelief Valve Cover O-ringDiaphragm NutRelief Valve DiaphragmReli

Page 6

6Servicing First & Second Check ValvesSeries 919 and LF9191⁄4" – 2" (8 – 50mm)NOTES: 1. No special tools are required to service the Se

Page 7 - Check Valve Kits

7*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.Servicing First & Second Check Valve

Page 8 - Troubleshooting Guide

RP/IS-919 1145 EDP# 1915346 © 2012 WattsUSA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.comCanada: Tel: (905) 332-4090 • Fax: (905) 332

Related models: 919

Comments to this Manuals

No comments